Maxgeek HAT520N Automatic Transfer Switch Controller Generator Set Dual Power Supply ATS Control Panel Description: -The powerful microprocessor contained within the HAT520N ATS controller allows for precision voltage (2-way 3-phase/single phase) measuring and make accurate judgment on abnormal voltage (power lost, over/under voltage, over/under frequency, loss of phase, phase sequence wrong) and control ATS to transfer after the delay has expired. This controller is suitable for NO Breaking ATS. When 1# power is abnormal, the controller will send signal to start genset after the "1# abnormal delay" has expired. "Three remote" (remote control, remote measurement and remote communication).
Function can be implemented with the help of LINK communication port. Specification: Function Item: parameter Display: LED AC System: 1P2W/2P3W/3P4W Alternator Frequency: 50/60Hz Monitor Interface: LINK Programmable Interface: LINK Applicable Switch Type: no break position DC Supply: AC 170277V Case Dimensions (mm): 13912050 (LWH) Panel Cutout (mm): 130111 Operating Temperature: -25+70? Measure and display 2-way 3 phase voltage and frequency. Over/under voltage, loss of phase, phase sequence wrong, over/under frequency protection function. As default, phase sequence wrong protection and over/under frequency protection are disable; however, users can set the protection function as need.
Parameters can be set via PC software using SG72 module (USB to LINK) or other converse module. The voltage normal delay of 1# or 2# can be set in (0-60) seconds and the genset start delay can be set in (0-3600) seconds. The voltage abnormal delay of 1# or 2# can be set in (0-60) seconds and the genset stop delay can be set in (0-3600) seconds.
1# power priority, Auto/Manual, "No priority" and "2# power priority" can be set via controller front panel. Closing output signal can be set as on intervals or as continuous output. Applicable for 2 isolated neutral line.In manual mode, ATS transfer 1# switch or 2# switch can be implemented via panel push button. LED mounted on front panel can clearly show ATS running status. The output contact capacity of 1# and 2# power supply transfer relay (1# CLOSE, 2# CLOSE) is 16A AC250V, volts-free contact, can be directly used in driving switch to transfer.
The output contact capacity of genset start relay (GENS START) is 7A AC250V/ 7A DC28V, volts-free N/C contact. Suitable for various AC systems (3 phase 4-wires, 2-phase 3-wires and single-phase 2-wire). Modular design, self extinguishing ABS plastic shell, pluggable terminal built-in mounting, compact structure with easy installation. Package List: 1 x ATS Controller.Usually it costs about 30USD-50USD. If you receive the item that not satisfied or defective, please do not open case and kindly notify us within 30 days.